Syringe Assembly
Specs
- Product: Medical Syringe (1.0 ml and 3.0 ml)
- Performance: 1800 pph
- Cycle time: 2.0 s
- Efficiency: 85%
- Pallet Transfer System: Lanco HLF2002-S
Sequence of Operation
- Load syringe body onto the pallet (manual)
- Dispense silicone mist into syringe (auto)
- Bowl feed of loaf seal to pallet (auto; system will reject incorrect orientation of the seal)
- Bowl feed and assemble plunger rod to seal (auto)
- System confirms correct plunger (auto)
- Transfer plunger-seal subassembly to syringe body (auto)
- Pressure test syringe assembly: push-return test (auto)
- System determinse product status - good or reject (auto)
- Off-load syringe to conveyor (auto)
|
|
|
-
Lanco AG
Gurzelenstrasse 14
CH-4512 Bellach
Tel: ++41 (0)32 617 38 00
Fax: ++41 (0)32 617 38 01
E-Mail: info@lanco.ch
|